Viewing file: umax.conf (3.02 KB) -rw-r--r-- Select action/file-type: (+) | (+) | (+) | Code (+) | Session (+) | (+) | SDB (+) | (+) | (+) | (+) | (+) | (+) |
# # Options for the umax backend #
# define scsi queueing depth #option scsi-maxqueue 2
# define scsi buffer size in bytes #option scsi-buffer-size-min 65536 #option scsi-buffer-size-max 262144
# define scan lines that shall be read in one block #option scan-lines 100 #option preview-lines 20
# define how to handle bad sense codes # 0 = handle as device busy # 1 = handle as ok # 2 = handle as i/o error # 3 = ignore bad error code - continue sense handler, #option handle-bad-sense-error 0
# define if a request sense command shall be executed #option execute-request-sense 0
# define if the preview bit shall be set when scanning in rgb mode #option force-preview-bit-rgb 0
# define if slow speed flag shall be set # BE CAREFUL WITH THIS OPTION, IT MAY DESTROY YOUR SCANNER WHEN SET FALSE # -1 = automatically set by driver - if known # 0 = disabled # 1 = enabled #option slow-speed 0
# define if care-about-smeraring flag shall be set # BE CAREFUL WITH THIS OPTION, IT MAY DESTROY YOUR SCANNER WHEN SET FALSE # -1 = automatically set by driver - if known # 0 = disabled # 1 = enabled #option care-about-smearing 0
# define if the calibration shall be done for selected scanarea or for each ccd pixel # -1 = automatically set by driver - if known # 0 = disabled # 1 = enabled #option calibration-full-ccd 1
# define if an offset of the calculate calibration with has to be used # -99999 = auto #option calibration-width-offset -99999
# define the number of pixels that is used for calibration # -1 = disabled # 0 = not set # 1 = 1 byte/pixel, # 2 = 2 bytes/pixel #option calibration-bytes-pixel -1
# define if scanner uses the same exposure times for red, green and blue # -1 = automatically set by driver - if known # 0 = disabled (own selection for red, green and blue) # 1 = enabled (same values for red, green and blue) #options exposure-time-rgb-bind 0
# define if shading data shall be inverted befor sending it back to the scanner # -1 = automatically set by driver - if known # 0 = disabled # 1 = enabled #option invert-shading-data 0
# define if the scanner supports lamp control commands # 0 = automatically set by driver - if known # 1 = enabled #option lamp-control-available 0
# define how 16 bit gamma data is padded # -1 = automatically set by driver - if known # 0 = gamma data is msb padded # 1 = gamma data is lsb padded #option gamma-lsb-padded 0
# define connection type of following devices # 1 = scsi # 2 = usb #option connection-type 1
# linux device identification: #scsi vendor model type bus channel id lun scsi UMAX * Scanner scsi LinoHell JADE scsi LinoHell Office scsi LinoHell Office2 scsi LinoHell SAPHIR2 scsi LinoHell SAPHIR3 scsi Linotype SAPHIR4 scsi LinoHell OPAL2 scsi HDM LS4H1S scsi Nikon AX-110 scsi Nikon AX-210 scsi KYE ColorPage-HR5 scsi EPSON Perfection600 scsi ESCORT "Galleria 600S" scsi TriGem PowerScanII
# Umax Astra 2200 via USB: # usb vendor product usb 0x1606 0x0230
# scsi device list option connection-type 1 /dev/scanner
# usb device list option connection-type 2 /dev/usbscanner
|